[See also regulations 67; 68]
Lairages and holding pens -
a) | may not be closer than six meters from, and not be situated higher than the abattoir; |
b) | must be constructed of cleanable, non-absorbent and durable material; |
c) | must be so constructed and maintained to avoid injury of animals; |
d) | must have sides not less than 1.8m in height for cattle and horses and one meter for sheep, goats and pigs; |
e) | must have permanent floors that are curbed and drained; |
f) | must be so constructed to render the floors and drain covers non-slippery; |
g) | must be fitted with gates which are a minimum of 800mm wide for sheep, goats, calves and pigs and 1800mm for cattle and horses; |
h) | must be roofed where pigs and sheep or goats are kept; |
i) | must be equipped with cold water sprayers for pigs; |
j) | must be fitted with water troughs at a height of 900mm for cattle and horses and 300mm for sheep, goats or pigs or water nipples for pigs; |
k) | must have well drained manure slabs for kraal manure prior to removal except if manure is removed directly into a vehicle; |
l) | must be provided with wash points, hoses and reels; and |
m) | used to isolate suspect animals must in addition to above have solid walls and gate and must not drain across other pens or pose any other contamination risk. |